Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Heil Hot Surface Igniter Kit for RGS121LTAB0AAAA — OEM Ignitor + Wiring | Ships Today
ICP

Heil Hot Surface Igniter Kit for RGS121LTAB0AAAA — OEM Ignitor + Wiring | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter kit for the ICP / Heil / Tempstar RGS121LTAB0AAAA gas furnace includes the igniter element (part #1171306) and the matching igniter wiring kit/harness (part #1188370). On each call for heat, the control board sends voltage to the igniter, which glows hot enough to ignite the gas at the burners. Hot surface igniters are a wear item — the brittle silicon-carbide/nitride element degrades with every heating cycle and eventually cracks, producing a no-heat condition where the inducer and gas valve sequence but the burners never light. Replacing the element together with a fresh wiring harness restores reliable ignition.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter with Wiring Harness
Brand ICP (Heil / Tempstar / Comfortmaker)
Fit Genuine OEM
Application Gas furnace burner ignition

Compatibility

Designed for the ICP/Heil/Tempstar RGS121LTAB0AAAA gas furnace and related RGS121 series units using the same hot surface ignition system. Confirm igniter mounting and connector style against your original before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter. Never touch the new igniter element with bare fingers — skin oils shorten its life.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position and the wiring/connector routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw(s), and carefully lift out the cracked element.
  5. Install — Mount the new igniter in the same position, connect the new wiring kit, and route the harness clear of hot surfaces.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and the burners light within the normal trial-for-ignition period.

Signs You Need a Replacement

  • Furnace runs the ignition sequence but burners never light (no-heat).
  • Visible crack, chip, or broken tip on the igniter element.
  • Igniter does not glow, or glows weakly/unevenly.
  • Frayed, brittle, or melted igniter wiring/connector.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121LTAB0AAAA — OEM Ignitor + Wiring | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121LTAB0AAAA — OEM Ignitor + Wiring | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121LTAB0AAAA — OEM Ignitor + Wiring | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online