Overview

This OEM hot surface igniter (part number 1171306) with its matching wiring kit (part number 1188370) is the ignition source for your ICP Tempstar Heil RGS091LSAB0AAAA gas furnace. On a heat call the control board sends voltage to the igniter, which glows white-hot to light the burners. Igniters are brittle silicon-carbide or silicon-nitride elements that crack, develop hairline fractures, or simply wear out from thousands of heating cycles. The result is a furnace that clicks and tries to ignite but never lights, then locks out. Replacing the igniter — and the heat-stressed wiring connector with the included kit — restores reliable ignition.

Specifications

Spec Value
Part Number (Igniter) 1171306
Part Number (Wiring Kit) 1188370
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Application Gas Furnace Ignition
Includes Igniter + Wiring Harness Kit

Compatibility

Directly fits ICP Tempstar Heil model RGS091LSAB0AAAA and related ICP-family gas furnaces using this hot surface igniter. The included wiring kit ensures a clean, heat-rated connection. Verify igniter mounting and connector style against your existing part before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/blower service panel.
  3. Document — Photograph the igniter mount and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out — handle only by the ceramic base.
  5. Install — Mount the new igniter without touching the element, install the new wiring kit, and reconnect.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace clicks and attempts ignition but burners never light.
  • Visible cracks or breaks in the igniter element.
  • Igniter does not glow on a heat call.
  • Furnace locks out after several failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS091LSAB0AAAA — With Wiring Harness | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS091LSAB0AAAA — With Wiring Harness | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS091LSAB0AAAA — With Wiring Harness | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.