This OEM hot surface igniter electrode (P/N 1179966) is the component that lights the burners in your ICP RGS214HDAA0AAAA gas furnace. On each heat call the control board sends voltage to the igniter, which glows red-hot and ignites the gas as the valve opens. Igniters are a wear item — the silicon carbide or nitride element becomes brittle over years of thermal cycling and eventually cracks. The most common failure symptom is a furnace that runs the inducer and blower but never produces heat, often locking out after several failed ignition attempts.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter / Electrode
Brand ICP / Tempstar / Heil
Supply Voltage 120V
Application Gas Furnace Ignition

Compatibility

Designed for the ICP RGS214HDAA0AAAA and the broader ICP family of gas furnaces sold under Tempstar, Heil, and Comfortmaker labels. Verify the mounting bracket and connector style against your existing igniter before installing.

Installation Guide

  1. Safety First — Shut off the furnace at the switch and breaker, close the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and its wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle only by the ceramic base — never touch the element.
  5. Install — Seat the new igniter so the element aligns with the burner flame path, secure the screw, and reconnect.
  6. Test — Restore power and gas, start a heat cycle, and confirm the igniter glows and burners light promptly.

Signs You Need a Replacement

  • Furnace inducer and blower run but no heat is produced.
  • Cracked, chipped, or visibly broken igniter element.
  • Igniter no longer glows during a heat call.
  • Furnace locks out after repeated failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS214HDAA0AAAA — Direct-Replacement Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS214HDAA0AAAA — Direct-Replacement Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS214HDAA0AAAA — Direct-Replacement Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online