Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
Heil Hot Surface Igniter for RGS150LFAA0AKAA — with Wiring Kit | Ships Today
ICP

Heil Hot Surface Igniter for RGS150LFAA0AKAA — with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter kit fits the ICP / Tempstar / Heil RGS150LFAA0AKAA gas furnace. The igniter is a brittle ceramic element that glows red-hot when the control board energizes it, lighting the burners at the start of each heat cycle. Over thousands of cycles the element develops hairline cracks and eventually opens, leaving you with a furnace that runs the inducer and blower but never produces heat. This listing includes OEM igniter 1171306 and the matching igniter wiring kit 1188370, so you get both the element and the harness/connector needed for a clean replacement. Typical failure symptoms are no ignition, the furnace locking out after several trial-for-ignition attempts, or a visibly cracked igniter that no longer glows.

Specifications

Spec Value
Part Number 1171306 (igniter) + 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Includes Igniter element and wiring/connector kit

Compatibility

Factory replacement for the ICP RGS150LFAA0AKAA and shared across many Tempstar, Heil, Comfortmaker, and Day & Night furnaces that use this hot surface igniter platform. Verify your existing igniter mounting bracket and connector against the kit before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter — handle the new one by the ceramic base only, never the element.
  5. Install — Mount the new igniter, route the new wiring kit, and reconnect the harness per your photo.
  6. Test — Restore gas and power and watch a full ignition cycle to confirm the burners light promptly.

Signs You Need a Replacement

  • Furnace runs inducer and blower but burners never light
  • Control board locks out after repeated ignition attempts
  • Igniter shows visible cracks or no longer glows orange
  • Intermittent no-heat calls that clear after a reset

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150LFAA0AKAA — with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150LFAA0AKAA — with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150LFAA0AKAA — with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online