Overview

This OEM hot surface igniter (part #1171306) is the component that ignites the burners on your ICP Tempstar Heil RGS121LFAB0AAAA gas furnace. On each heat call the control board sends voltage to the igniter, which glows white-hot to light the gas as it flows across the burners. Hot surface igniters are fragile and degrade with every cycle — the silicon carbide or nitride element eventually cracks, oxidizes, or breaks, leaving the furnace unable to light. This listing includes the matching igniter wiring kit (part #1188370) for a clean, reliable connection. Typical failure symptoms are no heat, a furnace that clicks and tries to start but never ignites, repeated lockouts, or a visibly cracked or broken igniter element.

Specifications

Spec Value
Part Number 1171306 (Igniter)
Included Kit 1188370 (Igniter Wiring Kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Application Gas Furnace Ignition
Fitment OEM Replacement

Compatibility

Direct-fit OEM replacement for the ICP Tempstar Heil RGS121LFAB0AAAA and related RGS-series furnaces using OEM igniter 1171306. The bundled wiring kit 1188370 ensures a correct, sealed connection to the furnace harness.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position and wiring before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old igniter by its base only.
  5. Install — Mount the new igniter (never touch the element), attach the wiring kit, and seat the connector firmly.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm a steady glow and burner light-off.

Signs You Need a Replacement

  • No heat — furnace tries to start but burners never light
  • Visibly cracked, chipped, or broken igniter element
  • Igniter no longer glows during a heat call
  • Repeated ignition lockouts or short-cycling on heat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121LFAB0AAAA — With Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121LFAB0AAAA — With Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121LFAB0AAAA — With Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online