OEM Carrier 50VA Control Transformer 120/208/240–12/24V for Model YAC1840YACX101K

This is the factory-specified OEM replacement control transformer (Part # P201-35150) for the Carrier YAC1840YACX101K HVAC system. The transformer steps down high-voltage line power (120/208/240 VAC) to the safe low-voltage signal (12/24 VAC) that powers your system's control board, thermostat, and all low-voltage control circuits. When this transformer fails, the entire control circuit goes dark — the thermostat loses power, the system won't respond to any call for heating or cooling, and the blower may run continuously or not at all. Replacing the transformer with the correct OEM part restores full system control immediately.

  • Specs: 50 VA rating | Primary: 120/208/240 VAC | Secondary: 12/24 VAC | 60 Hz | Single phase | CSA listed | OEM Part # P201-35150
  • OEM vs Generic: This OEM transformer is factory-wound to exact VA and voltage tolerances for the Carrier YAC1840YACX101K. Generic transformers often underperform at rated VA, causing nuisance tripping of the internal fuse and premature control board failure.
  • Install Difficulty: 2/5 — Disconnect power at the breaker before beginning. Tools needed: flathead and Phillips screwdrivers, wire stripper, multimeter (to verify 24V output after install). Label all wiring before removal. Replace the inline 3A fuse on the secondary circuit if it has blown.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed as the direct OEM replacement for Carrier model YAC1840YACX101K. Verify your existing transformer's VA rating and primary/secondary voltages against your unit's data plate before ordering. Have a fitment question? Our HVAC parts specialists confirm compatibility before you buy — reach out before placing your order.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my Carrier OEM Carrier Transformer 50VA 120/240-24V — YAC1840YACX101K?
Yes. This is the factory-specified OEM transformer for the Carrier OEM Carrier Transformer 50VA 120/240-24V — YAC1840YACX101K. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my Carrier OEM Carrier Transformer 50VA 120/240-24V — YAC1840YACX101K?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.