Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Transformer 50VA 120/240-24V — UPFLOW150UAHAC14A
Carrier

OEM Carrier Transformer 50VA 120/240-24V — UPFLOW150UAHAC14A

SKU: CARRIE-UPFLOW150UAHAC14A-TRANSFORMER-P201-35150 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 50VA Control Transformer 120/240–24V for Model UPFLOW150UAHAC14A

This factory-original step-down transformer is the exact OEM replacement for the Carrier UPFLOW150UAHAC14A upflow air handler. The transformer converts high-voltage line power (120/208/240 VAC) down to the safe 24V control-circuit voltage required by your thermostat, control board, relay coils, and other low-voltage components. When this transformer fails, the entire control circuit loses power — you'll see a blank thermostat display, no response to heating or cooling calls, or a blown fuse on the control board with no apparent cause. Replacing it with the genuine OEM part (P201-35150) restores exact factory voltage regulation and protects all downstream electronics.

  • Specs: 50VA rating | Primary: 120/208/240 VAC | Secondary: 12/24 VAC | Single phase | 60 Hz | CSA listed | Round foot-mount housing
  • OEM vs Generic: OEM transformers are wound to exact factory VA and voltage tolerances, ensuring stable 24V output under load. Off-brand units often run high secondary voltage, which can damage control boards and shorten thermostat life.
  • Install difficulty: 2/5 — Shut off all power at the breaker and disconnect switch before starting. Tools needed: flathead and Phillips screwdrivers, wire stripper, multimeter. Photograph all wiring connections before removal. Verify secondary output voltage (should read ~24–28V) after installation before restoring the system to operation.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Engineered for the Carrier UPFLOW150UAHAC14A upflow air handler. Always verify your unit's control circuit voltage requirements match the 120/208/240 VAC primary and 24 VAC secondary specs before ordering. Have questions about fitment? Our HVAC parts specialists confirm compatibility before you buy — no guesswork required.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Transformer fit my Carrier OEM Carrier Transformer 50VA 120/240-24V — UPFLOW150UAHAC14A?
Yes. This is the factory-specified OEM transformer for the Carrier OEM Carrier Transformer 50VA 120/240-24V — UPFLOW150UAHAC14A. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the transformer on my Carrier OEM Carrier Transformer 50VA 120/240-24V — UPFLOW150UAHAC14A?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Photo wiring connections. Step 3: Disconnect wires from old transformer. Step 4: Remove mounting hardware. Step 5: Install new transformer, reconnect wires matching voltage ratings. Step 6: Verify 24V output with multimeter.
My thermostat has no power. What failed?
Thermostat with no display = failed 24V transformer (or blown control board fuse). Check the 3A/5A fuse on the control board first ($1–$5 fix). If fuse is good but no 24V output from transformer, replace transformer.
Is this transformer compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier transformer?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online