This is the factory OEM replacement contactor for the Carrier PY1PNA036060ADBA packaged heat pump / split-system unit. The contactor is a high-voltage relay that receives a 24V signal from the thermostat or control board and closes to allow line-voltage power to flow to the compressor and condenser fan motor. When the contactor fails — due to pitted contacts, a burned coil, or a stuck plunger — the system will either refuse to start entirely, run continuously without shutting off, or produce a loud chattering hum from the electrical panel or air handler cabinet.
Compatibility: Designed and factory-specified for the Carrier PY1PNA036060ADBA. Always cross-reference the OEM part number (HN51KB024) printed on your existing contactor's label to confirm an exact match before installation. Not sure it fits? Our HVAC parts specialists verify fitment before every order — reach out before you buy.