Order before 3PM CST — ships same day.
Standard delivery 2-5 business days. Express options at checkout.
OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This is the genuine OEM Carrier high pressure safety switch (Part # HK02ZA395) factory-specified for the Carrier PY1PEB048090ABAA packaged heat pump unit. The high pressure switch is a critical refrigerant-circuit safety device that monitors system discharge pressure at all times. When refrigerant pressure rises to an unsafe level — due to a dirty condenser coil, failed condenser fan, refrigerant overcharge, or restricted airflow — the switch opens at 395 PSI and interrupts the compressor circuit to prevent catastrophic compressor failure. The circuit resets when pressure drops back to 295 PSI. Symptoms of a failed switch include nuisance high-pressure lockouts, fault codes on the control board, or a compressor that shuts down shortly after starting even when system pressures are normal.
Compatibility: Direct OEM replacement for Carrier model PY1PEB048090ABAA. Also replaces legacy part numbers: 312926-217, 71267D1, HK02ZA380, HK02ZA396, HK02ZA400, HK02ZA401, HK02ZA435, HK02ZA500, and HK02ZA501. Verify the PSI rating on your existing switch before ordering. In stock and ready to ship — order now and get your system back online fast.