This OEM pressure switch kit includes both the high pressure switch (312926-252) and low pressure switch (312926-258) — the factory-specified refrigerant safety controls for the Carrier PH13NB030000AAAA heat pump system. These switches continuously monitor refrigerant circuit pressure and cut power to the compressor the moment pressure moves outside the safe operating envelope. A failed high pressure switch typically presents as nuisance compressor trips or a system that short-cycles and locks out on a high-pressure fault. A failed low pressure switch causes the compressor to shut down prematurely or prevents it from starting altogether, often mimicking a refrigerant-loss symptom even when charge is adequate.
Compatibility: Factory-matched for the Carrier PH13NB030000AAAA heat pump. Always verify OEM part numbers 312926-252 (high) and 312926-258 (low) against your unit's data plate and wiring diagram before installation. Have questions about fitment? Our HVAC parts specialists verify compatibility before you order — contact us today.