This is the OEM factory-specified high-fire pressure switch for the Carrier PG8MAA036045AAJA gas furnace. The pressure switch is a safety device that monitors the negative pressure (vacuum) created by the draft inducer motor. If the inducer is not operating at the correct RPM or the flue path is partially blocked, the switch will not close — preventing ignition and locking out the furnace. The most common symptom of a failed pressure switch is a furnace that starts the inducer motor, then shuts down before the igniter ever fires, often resulting in a fault code indicating a pressure switch error.
Compatibility: Designed for the Carrier PG8MAA036045AAJA gas furnace. Also fits many Carrier, Bryant, and Payne gas furnace models — verify the W.C. rating on your existing switch and cross-reference with HK06WC091 or its current supersession HK06MC110 before ordering. Our fitment team is available to confirm compatibility prior to purchase. Order now — in stock and ships today.