Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch HK06WC061 for LC350TM400696
Carrier

OEM Carrier Pressure Switch HK06WC061 for LC350TM400696

SKU: CARRIE-LC350TM400696-PRESSURE_SWITCH-HK06WC061 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch HK06WC061 for Model LC350TM400696

This is the factory OEM replacement pressure switch (part number HK06WC061) for the Carrier LC350TM400696 furnace. The pressure switch is a critical safety component that monitors the negative pressure (inches of water column) created by the inducer draft motor before allowing the ignition sequence to proceed. If the switch fails to close — or closes prematurely — the control board will lock out the furnace and prevent heating. Common symptoms include a furnace that starts the inducer but never advances to ignition, a flashing fault code indicating a pressure switch error, or a unit that intermittently loses heat during cold weather demand.

  • Specs: OEM part number HK06WC061 | Factory-calibrated W.C. (water column) rating | Single-port diaphragm-style pressure switch | Direct factory replacement for Carrier LC350TM400696
  • OEM vs Generic: The OEM Carrier pressure switch is precision-calibrated to the exact W.C. rating required by your furnace's inducer assembly. Generic substitutes often carry wider tolerances, risking nuisance lockouts in cold weather or, more dangerously, failure to detect a true blocked-flue condition.
  • Install difficulty: 2/5 — Disconnect power and gas before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, and a manometer if verifying inducer static pressure. Inspect the rubber hose port for cracks or blockages before installing the new switch, as a deteriorated hose is a common root cause of switch failure.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our climate-controlled parts warehouse.

Compatibility: Designed as a direct OEM fit for the Carrier LC350TM400696 furnace. Always verify the existing part number printed on the switch body and confirm your model and serial number on the unit's data plate before ordering. Our parts specialists are available to confirm fitment — reach out before you order if you have any questions. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier LC350TM400696?
Yes. This is the factory-specified OEM pressure switch for the Carrier LC350TM400696. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier LC350TM400696?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online