OEM Carrier Pressure Switch HK06WC061 for Model LC350TM400568

This OEM pressure switch (part number HK06WC061) is the factory-specified replacement for the Carrier LC350TM400568 furnace. The pressure switch is a critical safety component that monitors negative pressure created by the inducer draft motor before allowing the ignition sequence to proceed. If the switch fails to close — or is stuck open — the control board will lock out the furnace, resulting in no heat and often a diagnostic fault code indicating a pressure switch fault.

  • Specs: OEM part number HK06WC061 | Factory-calibrated W.C. (water column) rating | Single-port pressure switch | 24V control circuit compatible | Designed for Carrier LC350TM400568 induced-draft gas furnace
  • OEM vs Generic: This is a genuine OEM Carrier pressure switch, calibrated to exact factory W.C. specifications. Aftermarket substitutes often carry looser pressure tolerances, which can cause nuisance lockouts or — more dangerously — allow ignition under unsafe draft conditions.
  • Install difficulty: 2/5 — Shut off gas and power at the disconnect before beginning. Tools needed: flathead screwdriver, needle-nose pliers, and a manometer (recommended to verify draft pressure). Photograph hose routing and wiring before disconnecting. Inspect the rubber hose for cracks or blockages before installing the new switch.
  • Warranty: 1-year OEM factory warranty against defects in materials and workmanship. Orders placed before cutoff ship same business day from our warehouse.

Compatibility: This pressure switch is engineered specifically for the Carrier LC350TM400568 furnace. Always verify the existing part number on the switch body or your unit's wiring diagram before ordering to ensure correct W.C. rating and port configuration. Our fitment team is available to confirm compatibility before you buy — same-day shipping available on all in-stock OEM parts.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier LC350TM400568?
Yes. This is the factory-specified OEM pressure switch for the Carrier LC350TM400568. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier LC350TM400568?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.