OEM Carrier Pressure Switch HK06WC061 for Model LC350LC400679

This is the OEM factory-specified pressure switch (part number HK06WC061) for the Carrier LC350LC400679 furnace. The pressure switch is a critical safety component that monitors the negative pressure created by the inducer draft motor before allowing the ignition sequence to proceed. When the switch fails or its diaphragm cracks, the furnace control board cannot confirm safe venting conditions — resulting in a no-heat lockout, a flashing fault code, or a system that attempts ignition and immediately shuts down without ever firing the burners.

  • Specs: OEM part number HK06WC061 | Factory-calibrated W.C. (water column) rating | Single-port diaphragm-style switch | 24V control circuit compatible | Direct plug-in hose and terminal connections
  • OEM vs Generic: OEM pressure switches are factory-calibrated to the exact W.C. rating required by the LC350LC400679. Generic replacements with slightly off-spec trip points can cause nuisance lockouts in cold weather or, worse, allow ignition under unsafe draft conditions — always choose OEM for safety-critical components.
  • Install Difficulty: 2/5 — Power down and disconnect the furnace before beginning. Tools needed: flathead screwdriver, needle-nose pliers, multimeter (continuity test). Disconnect the rubber hose and two-wire harness, swap the switch, and confirm continuity closes when inducer is running. Label hose port orientation before removal.
  • Warranty: 1-year OEM factory warranty against defects. In-stock units ship the same business day from our warehouse.

Compatibility: Designed as a direct OEM replacement for Carrier model LC350LC400679. Always verify your existing switch's W.C. rating stamped on the body matches before installing. If you are unsure of fitment, our HVAC parts specialists can confirm compatibility before you order. Order today and your part ships same business day.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier LC350LC400679?
Yes. This is the factory-specified OEM pressure switch for the Carrier LC350LC400679. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier LC350LC400679?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.