Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch HK06WC061 for LC350LC400467
Carrier

OEM Carrier Pressure Switch HK06WC061 for LC350LC400467

SKU: CARRIE-LC350LC400467-PRESSURE_SWITCH-HK06WC061 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch HK06WC061 for Model LC350LC400467

This OEM pressure switch (part number HK06WC061) is the factory-specified replacement for the Carrier LC350LC400467 furnace. The pressure switch is a critical safety component that monitors negative pressure created by the inducer draft motor. Once the inducer reaches proper speed and airflow, the switch closes to signal the control board that it is safe to proceed with ignition. When this switch fails — whether due to a ruptured diaphragm, stuck contacts, or a blocked sensing port — the furnace will lock out before ignition, leaving you with no heat and typically a diagnostic fault code indicating a pressure switch error.

  • Specs: OEM part number HK06WC061 | Factory-calibrated W.C. (water column) rating | Single-port pressure switch | Direct drop-in replacement with matching hose barb and electrical connector
  • OEM vs Generic: This is a genuine Carrier OEM pressure switch, calibrated to the exact water column rating required by the LC350LC400467. Aftermarket substitutes often carry looser trip-point tolerances, which can cause nuisance lockouts or, worse, fail to detect a true draft fault — a safety risk.
  • Install difficulty: 2/5 — Disconnect power before servicing. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, and a phone or camera to photograph hose and wire routing before removal. Check the rubber sensing hose for cracks or blockages while the panel is open.
  • Warranty: 1-year OEM factory warranty. Orders placed before cutoff ship same business day from our dedicated HVAC parts warehouse.

Compatibility: Designed for the Carrier LC350LC400467 furnace. Always verify your existing switch's W.C. rating and hose port configuration against your unit's data plate and wiring diagram before ordering. If you have any questions about fitment, our HVAC parts specialists are ready to confirm compatibility before you buy — same-day shipping guaranteed on in-stock OEM parts.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier LC350LC400467?
Yes. This is the factory-specified OEM pressure switch for the Carrier LC350LC400467. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier LC350LC400467?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.