OEM Carrier Contactor 2-Pole 24V Coil for GC060HSRCXET1XX1
Carrier

OEM Carrier Contactor 2-Pole 24V Coil for GC060HSRCXET1XX1

SKU: CARRIE-GC060HSRCXET1XX1-CONTACTOR-HN52TC040 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor HN52TC040 for Model GC060HSRCXET1XX1

This is the factory OEM replacement contactor (part number HN52TC040) for the Carrier GC060HSRCXET1XX1 packaged unit. The contactor is a high-voltage relay that bridges the gap between your 24V thermostat signal and the 240V power supply feeding the compressor and condenser fan motor. When the contactor fails — whether from burned contacts, a welded armature, or a failed coil — the system will either refuse to start entirely or run continuously without responding to thermostat commands. Replacing a failed contactor is one of the most common and cost-effective HVAC repairs available.

  • Specs: 2-pole configuration | 24V AC coil voltage | 40-amp rated contacts | 240V line voltage | Direct OEM replacement for part number HN52TC040
  • OEM vs Generic: OEM contactors use silver-alloy contact tips rated to exact factory amp draw specifications, resisting pitting and arcing over thousands of switching cycles. Generic contactors often use inferior contact materials that corrode faster, leading to repeat failures within one to two seasons.
  • Install difficulty: 2/5 — Shut off all power at the disconnect and breaker before starting. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all high-voltage wiring connections before removing the old contactor to ensure correct reinstallation.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our stocked warehouse.

Compatibility: Designed as a direct OEM drop-in replacement for the Carrier GC060HSRCXET1XX1 packaged unit. Always verify pole count, coil voltage, and amperage rating on your unit's data plate before ordering. Our fitment team is available to confirm compatibility before you buy — just reach out with your model and serial number. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier GC060HSRCXET1XX1?
Yes. This is the factory-specified OEM contactor for the Carrier GC060HSRCXET1XX1. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier GC060HSRCXET1XX1?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.