Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 24V Coil for GC060HSLCDET1XX1
Carrier

OEM Carrier Contactor 2-Pole 24V Coil for GC060HSLCDET1XX1

SKU: CARRIE-GC060HSLCDET1XX1-CONTACTOR-HN52TC040 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Contactor 2-Pole 24V Coil for Model GC060HSLCDET1XX1

This is the factory OEM replacement contactor (part number HN52TC040) for the Carrier GC060HSLCDET1XX1 packaged unit. The contactor is the high-voltage switching relay that receives a 24V signal from your thermostat or control board and closes the circuit to energize the compressor and condenser fan motor. When a contactor fails — due to pitted contacts, a burned coil, or a stuck plunger — the most common symptoms are an air conditioner that won't turn on at all, a unit that hums without the compressor starting, or one that runs continuously without cycling off. Replacing a failed contactor promptly protects downstream components like the compressor from voltage irregularities.

  • Specs: 2-pole configuration | 24V AC coil voltage | Rated for high-amperage compressor and fan loads | Direct OEM replacement for part number HN52TC040
  • OEM vs Generic: This OEM contactor is manufactured to Carrier's exact coil pull-in voltage, contact material, and amperage specifications. Generic contactors may use lower-grade contact alloys that pit faster and introduce resistance, shortening compressor life over time.
  • Install Difficulty: 2/5 — Always shut off power at the disconnect and breaker panel before beginning. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old contactor to ensure correct re-termination.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed before cutoff ship same business day from our stocked warehouse.

Compatibility: Designed specifically for the Carrier GC060HSLCDET1XX1 packaged unit. Always verify the OEM part number HN52TC040 against your unit's data plate or existing contactor label before ordering. Our HVAC parts specialists are available to confirm fitment prior to purchase — same-day shipping available on all in-stock orders.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier GC060HSLCDET1XX1?
Yes. This is the factory-specified OEM contactor for the Carrier GC060HSLCDET1XX1. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier GC060HSLCDET1XX1?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online