OEM Carrier Contactor 2-Pole 24V Coil for Model GC036CBLCXET1XX1

This is the factory OEM replacement contactor (part number HN52TC040) for the Carrier GC036CBLCXET1XX1 condensing unit. The contactor is a high-voltage relay controlled by the 24V thermostat signal — when the stat calls for cooling, the contactor closes and sends line voltage to the compressor and condenser fan motor. A failed contactor is one of the most common reasons an air conditioner won't start. Symptoms include a system that hums but never engages, visible pitting or burning on the contactor contacts, or a unit that runs continuously without cycling off due to welded contacts.

  • Specs: 2-pole design | 24V AC coil voltage | Factory-rated amperage for 3-ton condensing load | Direct OEM replacement for part number HN52TC040
  • OEM vs Generic: This OEM contactor is manufactured to Carrier's exact specifications, including contact material grade and coil pull-in voltage. Generic contactors may use lower-grade contacts that pit faster under high cycling loads, reducing service life significantly in warm climates.
  • Install difficulty: 2/5 — Always disconnect power at the disconnect box before servicing. Tools needed: flat-head and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring before removal. Line voltage wires connect to line-side terminals; load wires connect to load-side terminals.
  • Warranty: 1-year OEM factory warranty. Orders placed before cutoff ship same business day from our HVAC parts warehouse.

Compatibility: Designed specifically for the Carrier GC036CBLCXET1XX1 condensing unit. Verify your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Our parts specialists are available to confirm fitment — reach out before you buy if you have any questions. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier GC036CBLCXET1XX1?
Yes. This is the factory-specified OEM contactor for the Carrier GC036CBLCXET1XX1. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier GC036CBLCXET1XX1?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.