Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 24V Coil for GC024VTRCDET1XX1
Carrier

OEM Carrier Contactor 2-Pole 24V Coil for GC024VTRCDET1XX1

SKU: CARRIE-GC024VTRCDET1XX1-CONTACTOR-HN52TC040 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Contactor 2-Pole 24V Coil for Model GC024VTRCDET1XX1

This is the factory OEM replacement contactor (part number HN52TC040) for the Carrier GC024VTRCDET1XX1 condensing unit. The contactor is a high-voltage relay that acts as the primary switch between your thermostat's 24V control signal and the high-voltage power feeding the compressor and condenser fan motor. When the contactor fails — whether due to worn contacts, a burned coil, or pitted contact points — the condenser unit will either fail to start entirely, run continuously without shutting off, or cycle erratically. Replacing the contactor is one of the most common and cost-effective AC repairs available.

  • Specs: 2-pole configuration | 24V AC coil voltage | Factory-rated amperage for GC024VTRCDET1XX1 | OEM part number HN52TC040 | Direct drop-in replacement, no modifications required
  • OEM vs Generic: This OEM Carrier contactor is manufactured to exact factory tolerances. Generic contactors may use lower-grade contact materials that pit and arc more quickly under load, leading to repeat failures. OEM ensures proper coil pull-in voltage and contact longevity under real operating conditions.
  • Install difficulty: 2/5 — Shut off power at the disconnect and breaker before beginning. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring connections before removal. Swap wires one at a time to avoid miswiring.
  • Warranty: 1-year OEM factory warranty. In stock and ships same business day from our warehouse.

Compatibility: Designed specifically for the Carrier GC024VTRCDET1XX1 condensing unit. Always verify your existing contactor's pole configuration, coil voltage, and amperage rating against your unit's data plate prior to ordering. Our fitment team is available to confirm compatibility before you buy — order with confidence and get your system back up and running fast.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier GC024VTRCDET1XX1?
Yes. This is the factory-specified OEM contactor for the Carrier GC024VTRCDET1XX1. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier GC024VTRCDET1XX1?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online