OEM Carrier 2-Pole Contactor 24V Coil for Model GC024HERCXET1XX1 (HN52TC040)

This is the factory OEM replacement contactor for the Carrier GC024HERCXET1XX1 split-system unit, sourced directly from Carrier under part number HN52TC040. The contactor is the high-voltage relay that connects and disconnects power to the compressor and condenser fan motor each time your thermostat calls for cooling. When the contactor fails — due to pitted contacts, coil burnout, or a stuck plunger — the system will either fail to start entirely, run continuously without shutting off, or trip the breaker repeatedly.

  • Specs: 2-pole configuration | 24V AC control coil | High-amperage load contacts | Factory-rated for R-410A system duty cycles | Direct OEM replacement for HN52TC040
  • OEM vs Generic: OEM contactors use factory-spec contact materials and coil windings, ensuring proper pull-in voltage and long service life. Generic contactors often use lower-grade contact alloys that pit and oxidize faster, leading to premature failure and potential compressor damage.
  • Install difficulty: 2/5 — Always disconnect power at the breaker and wait 5 minutes before servicing. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, needle-nose pliers, multimeter. Photograph all wiring connections before removing the old contactor.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed before cutoff ship the same business day from our climate-controlled warehouse.

Compatibility: Engineered specifically for the Carrier GC024HERCXET1XX1 split-system unit. Always verify your existing contactor's pole count, coil voltage, and amperage rating against your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists confirm fitment before you buy — no guesswork, no returns.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier GC024HERCXET1XX1 — HN52TC040?
Yes. This is the factory-specified OEM contactor for the Carrier GC024HERCXET1XX1 — HN52TC040. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier GC024HERCXET1XX1 — HN52TC040?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.