Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket for GB3AAV060115ACJA — HK06WC09
Carrier

OEM Carrier Pressure Switch w/ Bracket for GB3AAV060115ACJA — HK06WC09

SKU: CARRIE-GB3AAV060115ACJA-PRESSURE_SWITCH-HK06WC090 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch with Bracket for Model GB3AAV060115ACJA — Part# HK06WC090

This is the OEM factory-specified pressure switch with bracket for the Carrier GB3AAV060115ACJA gas furnace. The pressure switch is a critical safety component that monitors negative pressure created by the inducer draft motor to confirm proper venting before allowing the ignition sequence to proceed. When this switch fails or its sensing hose becomes cracked or clogged, the furnace control board detects an open circuit and locks out the system — typically resulting in a no-heat condition with a blinking fault code indicating a pressure switch error. Common symptoms include the inducer motor running continuously with no ignition attempt, or the furnace cycling repeatedly without ever reaching the heating stage.

  • Specs: Includes factory-matched bracket for direct OEM mounting | Water column (W.C.) rating factory-calibrated for the GB3AAV060115ACJA inducer assembly | Single-port or dual-port configuration per original design | 1/4" spade terminals for plug-and-play reconnection
  • OEM vs Generic: This OEM unit carries the exact W.C. rating engineered for this furnace. Aftermarket switches frequently ship with incorrect trip points, causing nuisance lockouts or — worse — failing to detect a true venting fault, which is a serious safety risk.
  • Install difficulty: 2/5 — Power down the furnace and allow the inducer to cool before beginning. Tools needed: 1/4" nut driver, flat-head screwdriver, needle-nose pliers. Inspect the rubber sensing hose for cracks or blockages before installing the new switch, as a damaged hose is a common root cause of switch failure.
  • Warranty: 1-year OEM factory warranty against defects in materials and workmanship. Orders received before cutoff ship same business day from our warehouse.

Compatibility: Engineered as a direct OEM replacement for the Carrier GB3AAV060115ACJA gas furnace. Always verify the W.C. rating stamped on your original switch matches this listing before ordering. Our fitment team is available to confirm compatibility — just reach out before you buy. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier GB3AAV060115ACJA — HK06WC09?
Yes. This is the factory-specified OEM pressure switch for the Carrier GB3AAV060115ACJA — HK06WC09. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier GB3AAV060115ACJA — HK06WC09?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online