OEM Carrier Pressure Switch w/ Bracket HK06WC090 for Model GB1AAV036045AEJA

This OEM pressure switch with mounting bracket is the factory-specified replacement for the Carrier GB1AAV036045AEJA gas furnace. The pressure switch monitors negative pressure created by the induced draft blower to confirm proper venting before allowing the ignition sequence to proceed. When the switch fails or its hose becomes cracked or clogged, the furnace control board receives no proof signal and locks out the system — typically displaying a fault code for a failed pressure switch or stuck open/closed switch. The result: no heat, even when the inducer motor is running normally.

  • Specs: OEM-rated water column (W.C.) pressure setting | Includes factory mounting bracket | Single-port hose connection | 24V control circuit compatible | Factory-matched trip point for GB1AAV036045AEJA inducer assembly
  • OEM vs Generic: OEM pressure switches are calibrated to the exact W.C. rating required by Carrier's furnace design. Off-spec generic switches can trip too early or too late, causing nuisance lockouts or — more dangerously — allowing operation under improper draft conditions.
  • Install difficulty: 2/5 — Power down and disconnect the furnace before beginning. Tools needed: Phillips screwdriver, 1/4" nut driver, needle-nose pliers. Inspect the rubber hose for cracks or moisture blockage before replacing the switch — a clogged hose is often the root cause of switch failure.
  • Warranty: 1-year OEM factory warranty. Ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed specifically for the Carrier GB1AAV036045AEJA gas furnace. Always verify your existing switch's W.C. rating and hose port configuration against the data plate and wiring diagram inside your furnace cabinet before ordering. Need fitment confirmation? Our HVAC parts specialists verify compatibility before you buy — no guesswork required.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier GB1AAV036045AEJA — HK06WC09?
Yes. This is the factory-specified OEM pressure switch for the Carrier GB1AAV036045AEJA — HK06WC09. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier GB1AAV036045AEJA — HK06WC09?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.