Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Pressure Switch w/ Bracket for GA2AAD036070ABJA — HK06WC09
Carrier

OEM Carrier Pressure Switch w/ Bracket for GA2AAD036070ABJA — HK06WC09

SKU: CARRIE-GA2AAD036070ABJA-PRESSURE_SWITCH-HK06WC090 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Pressure Switch with Bracket for Model GA2AAD036070ABJA (HK06WC090)

This is the factory-specified OEM pressure switch with mounting bracket for the Carrier GA2AAD036070ABJA packaged gas unit. The pressure switch monitors negative pressure created by the inducer draft motor to confirm safe venting conditions before allowing the ignition sequence to proceed. When this switch fails or becomes stuck open, the control board cannot verify inducer operation and the furnace will lock out entirely — producing a no-heat call with no spark or gas valve activity. A failed pressure switch is one of the most common causes of furnace lockout codes in colder months.

  • Specs: OEM Part# HK06WC090 | Includes factory mounting bracket | Rated water column (W.C.) matched to Carrier GA2AAD036070ABJA inducer specifications | Single-port or dual-port configuration as factory-designed
  • OEM vs Generic: OEM pressure switches are calibrated to the exact W.C. rating required by your unit's inducer. Generic or universal switches frequently use approximate W.C. ratings, causing nuisance lockouts or — more dangerously — allowing the furnace to fire under unsafe venting conditions. Always use OEM on pressure switches.
  • Install difficulty: 3/5 — Disconnect power and gas before beginning. Tools needed: 1/4" nut driver, flathead screwdriver, manometer (recommended to verify W.C. after install). Inspect the rubber hose connecting the switch to the inducer for cracks or blockages before replacing the switch, as a clogged hose is a common root cause of pressure switch failure.
  • Warranty: 1-year OEM factory warranty. In-stock and ships same business day from our warehouse.

Compatibility: Designed and factory-matched for the Carrier GA2AAD036070ABJA packaged gas unit. Verify OEM part number HK06WC090 against your unit's data plate or existing switch label before ordering. Not sure if this is the right part? Our HVAC parts specialists confirm fitment before you buy — no guesswork, no returns.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Pressure Switch fit my Carrier GA2AAD036070ABJA — HK06WC09?
Yes. This is the factory-specified OEM pressure switch for the Carrier GA2AAD036070ABJA — HK06WC09. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the pressure switch on my Carrier GA2AAD036070ABJA — HK06WC09?
Difficulty: Medium (20–30 min)
Step 1: Turn off power. Step 2: Locate pressure switch near draft inducer. Step 3: Note tubing orientation. Step 4: Disconnect tubing and wires. Step 5: Remove screw, install new switch. Step 6: Reconnect tubing and wires, restore power.
My furnace shows a pressure switch error. What do I replace?
Furnace LED showing pressure switch error = switch not detecting draft inducer airflow. Try first: clear the rubber tubing to the switch (often clogged with condensation). If problem persists, replace the pressure switch.
Is this pressure switch compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier pressure switch?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.