OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This is the factory OEM high pressure switch (part number HK02ZA442) designed specifically for the Carrier FIOP100E301GA. The pressure switch is a critical safety component in your HVAC system — it monitors flue gas pressure to confirm the inducer motor is operating correctly before allowing the ignition sequence to proceed. When this switch fails or sticks open, the control board receives no proof-of-pressure signal, resulting in a system lockout, no-heat condition, or repeated failed ignition attempts. Common symptoms include the inducer running but the burners never lighting, error codes indicating a pressure switch fault, or the system cycling on and off without producing heat.
Compatibility: Engineered as the direct OEM replacement for the Carrier FIOP100E301GA. Always cross-reference the W.C. rating stamped on your existing switch and confirm the model number on the unit data plate prior to ordering. If you need fitment assistance, our HVAC parts specialists are available to verify compatibility before you buy. In stock — ships today.