Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Fan Blower Control Board HK61EA006 — FA4CNC024008AAAA
Carrier

OEM Carrier Fan Blower Control Board HK61EA006 — FA4CNC024008AAAA

SKU: CARRIE-FA4CNC024008AAAA-CONTROL_BOARD-HK61EA006 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Fan Blower Control Board HK61EA006 for Model FA4CNC024008AAAA

This is the factory OEM replacement fan blower control board (part number HK61EA006) designed specifically for the Carrier FA4CNC024008AAAA air handler unit. The blower control board serves as the command center for your air handler's indoor blower motor — managing fan speed sequencing, timing delays, and communication with the thermostat and system controls. When this board fails, symptoms typically include the blower motor not running at all, erratic or continuous fan operation, improper speed staging, or the system entering a fault lockout condition with no airflow to the conditioned space.

  • Specs: OEM part number HK61EA006 | Factory-programmed for Carrier FA4CNC024008AAAA air handler | 24V control circuit compatible | Pre-set fan delay and speed profiles matched to factory specifications
  • OEM vs Generic: This is a genuine Carrier OEM board with factory-programmed logic. Aftermarket boards often require manual DIP switch configuration and may not replicate exact delay timing or multi-speed motor control, potentially causing premature motor wear or comfort complaints.
  • Install difficulty: 3/5 — Disconnect power at the breaker before beginning. Tools needed: Phillips and flathead screwdrivers, needle-nose pliers, phone or camera for wiring documentation, and a multimeter for post-install verification. Photograph all wire harness connections before removal. Label each connector if needed. The board mounts with standard standoffs and plugs into existing harnesses.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our climate-controlled warehouse.

Compatibility: Engineered as a direct OEM replacement for the Carrier FA4CNC024008AAAA fan coil air handler. Always verify the part number printed on your existing board before ordering, as neighboring model variants may use a different board revision. Our fitment team is available to confirm compatibility before you purchase — same-day shipping available on all in-stock orders placed before 3 PM EST.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Fan Blower Control Board HK61EA006 — FA4CNC024008AAAA?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Fan Blower Control Board HK61EA006 — FA4CNC024008AAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Fan Blower Control Board HK61EA006 — FA4CNC024008AAAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online