OEM Carrier Fan Blower Control Board HK61EA002 for Model FA4ANC042010AGAA

This is the factory-original fan blower control board (OEM part number HK61EA002) for the Carrier FA4ANC042010AGAA air handler. The integrated fan control (IFC) board is the nerve center of your air handler — it governs blower motor speed sequencing, heating and cooling delay timings, and communicates fault codes through onboard LED diagnostics. When this board fails, common symptoms include the blower motor refusing to start, running continuously regardless of thermostat demand, erratic multi-speed operation, or a complete system lockout with no response to thermostat signals.

  • Specs: OEM part number HK61EA002 | Factory-matched for Carrier FA4ANC042010AGAA air handler | 24V control circuit input | Compatible with single-stage cooling and multi-speed blower motor configurations | Onboard LED fault code indicator for simplified diagnostics
  • OEM vs Generic: This is a genuine Carrier OEM board programmed with factory blower delay timings and speed profiles. Aftermarket boards may require manual dip-switch configuration and often lack the precise sequencing needed to protect the compressor and heat exchanger, potentially shortening equipment life.
  • Install difficulty: 3/5 — Requires disconnecting low-voltage thermostat wiring, line-voltage blower motor leads, and transformer connections. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, phone camera (photograph all wiring before removal). Turn off power at the breaker AND the air handler disconnect before beginning. Transfer dip-switch settings from old board to new before powering up.
  • Warranty: 1-year OEM factory warranty against defects in materials and workmanship. Ships same business day from our climate-controlled warehouse in original manufacturer packaging.

Compatibility: Designed specifically for the Carrier FA4ANC042010AGAA residential air handler. Verify your existing board's part number against HK61EA002 before ordering. If your data plate or existing board label shows a different part number, contact our fitment team — we verify compatibility before your order ships so you get the right part the first time.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier OEM Carrier Fan Blower Control Board HK61EA002 — FA4ANC042010AGAA?
Yes. This is the factory-specified OEM control board for the Carrier OEM Carrier Fan Blower Control Board HK61EA002 — FA4ANC042010AGAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier OEM Carrier Fan Blower Control Board HK61EA002 — FA4ANC042010AGAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.