OEM Carrier Fan Blower Control Board HK61EA002 for FA4ANC018010AFAA

SKU: CARRIE-FA4ANC018010AFAA-CONTROL_BOARD-HK61EA002 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier Fan Blower Control Board HK61EA002 for Model FA4ANC018010AFAA

This is the factory OEM fan blower control board for the Carrier FA4ANC018010AFAA air handler. The integrated fan control (IFC) board is the central brain of your air handler — it sequences blower motor operation, monitors safety inputs, manages multi-speed fan functions, and coordinates communication between the thermostat and the rest of the system. When this board fails, common symptoms include the blower fan refusing to start, continuous fan operation that won't shut off, intermittent system lockouts, erratic blower speeds, or a completely unresponsive air handler despite the thermostat calling for heating or cooling.

  • Specs: OEM part number HK61EA002 | Factory-matched control logic for FA4ANC018010AFAA air handler | 24V control circuit compatible | Includes integrated fault code diagnostics via LED indicator
  • OEM vs Generic: This is a genuine Carrier OEM board pre-programmed with exact fan timing delays, safety lockout thresholds, and blower speed profiles for your specific model. Aftermarket boards often require manual dip-switch configuration and may not replicate factory timing sequences, risking premature motor wear or voided equipment warranties.
  • Install difficulty: 3/5 — Power down and lock out the air handler at the breaker before beginning. Tools needed: Phillips and flathead screwdrivers, needle-nose pliers, smartphone (to photograph all wiring connections before removal). Transfer wiring terminal by terminal and verify the board is fully seated before restoring power. A multimeter is recommended to confirm 24V control voltage before and after installation.
  • Warranty: 1-year OEM factory warranty against defects in materials and workmanship. Orders received before cutoff ship same business day from our climate-controlled warehouse.

Compatibility: Engineered as a direct OEM replacement for the Carrier FA4ANC018010AFAA air handler. Always cross-reference the part number printed on your existing board before ordering to confirm fitment. Our HVAC parts specialists are available to verify compatibility — contact us before you order if you have any questions. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my Carrier FA4ANC018010AFAA?
Yes. This is the factory-specified OEM control board for the Carrier FA4ANC018010AFAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my Carrier FA4ANC018010AFAA?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.