Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 24V Coil for CP50P250P206010CP
Carrier

OEM Carrier Contactor 2-Pole 24V Coil for CP50P250P206010CP

SKU: CARRIE-CP50P250P206010CP-CONTACTOR-HN53CD115 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor 24V Coil for Model CP50P250P206010CP

This OEM replacement contactor is the factory-specified part for the Carrier CP50P250P206010CP packaged unit. The contactor is a high-voltage relay that receives a 24V signal from the thermostat and control board, then closes its contacts to supply line voltage to the compressor and condenser fan motor. When the contactor fails — due to pitted contacts, a stuck or burned coil, or contact welding — the result is an air conditioning system that won't turn on, fails to cool, or runs continuously without shutting off.

  • Specs: 2-pole configuration | 24V AC coil voltage | Factory-rated amperage for Carrier packaged equipment | OEM part number HN53CD115
  • OEM vs Generic: This OEM contactor is manufactured to exact Carrier factory specifications, ensuring proper coil pull-in voltage, contact rating, and long service life. Generic contactors may use inferior contact materials that pit faster under load, leading to early failure and potential compressor damage.
  • Install difficulty: 3/5 — Always disconnect power at the disconnect box and verify zero voltage with a multimeter before beginning. Tools needed: flathead and Phillips screwdrivers, 1/4" nut driver, multimeter, needle-nose pliers. Photograph all wiring connections before removing the old contactor.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our warehouse when ordered before cutoff.

Compatibility: Designed specifically for the Carrier CP50P250P206010CP commercial packaged unit. Verify OEM part number HN53CD115 against your unit's data plate or existing contactor label before ordering. Our team is available to confirm fitment — don't hesitate to reach out before placing your order. Order now and get same-day shipping on this in-stock OEM part.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier CP50P250P206010CP?
Yes. This is the factory-specified OEM contactor for the Carrier CP50P250P206010CP. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier CP50P250P206010CP?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online