Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
OEM Carrier Contactor 2-Pole 24V Coil HN51JD026 — CH14NB06000GAAAA
Carrier

OEM Carrier Contactor 2-Pole 24V Coil HN51JD026 — CH14NB06000GAAAA

SKU: CARRIE-CH14NB06000GAAAA-CONTACTOR-HN51JD026 Brand: Carrier

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

OEM Carrier 2-Pole Contactor HN51JD026 for Model CH14NB06000GAAAA

This is the factory-specified OEM replacement contactor for the Carrier CH14NB06000GAAAA split-system air conditioner. The contactor is a high-voltage relay controlled by the 24V signal from your thermostat — when you call for cooling, the contactor closes and delivers line voltage to the compressor and condenser fan motor. A failed contactor is one of the most common reasons an AC condenser won't start: symptoms include the outdoor unit failing to energize, audible chattering or buzzing at the contactor, pitted or burnt contact points, or the contactor remaining stuck open or welded shut.

  • Specs: 2-Pole configuration | 24V AC coil voltage | Replaces OEM part number HN51JD026 | Factory-matched contact rating for Carrier 14 SEER condenser load requirements
  • OEM vs Generic: This OEM contactor uses factory-grade contact materials rated for the exact amp draw of the CH14NB06000GAAAA compressor. Generic contactors often use lower-grade alloys that pit and fail faster under high-cycle summer loads, risking compressor damage.
  • Install difficulty: 3/5 — Disconnect and lock out power at the disconnect box and breaker before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter, and insulated gloves. Photograph all wiring connections before removal. The line-voltage terminals carry 240V — always verify power is off with a multimeter before touching any wires.
  • Warranty: 1-year OEM factory warranty against defects. In-stock and ships same business day from our warehouse when ordered before 3 PM local time.

Compatibility: Designed and factory-specified for Carrier model CH14NB06000GAAAA split-system condensers. Verify your existing contactor's pole count and coil voltage on the data plate or old part before ordering. Not sure if this is the right part? Our HVAC parts specialists can confirm fitment — contact us before you order. Order now and get same-day shipping on this in-stock OEM part.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier OEM Carrier Contactor 2-Pole 24V Coil HN51JD026 — CH14NB06000GAAAA?
Yes. This is the factory-specified OEM contactor for the Carrier OEM Carrier Contactor 2-Pole 24V Coil HN51JD026 — CH14NB06000GAAAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier OEM Carrier Contactor 2-Pole 24V Coil HN51JD026 — CH14NB06000GAAAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online