OEM Carrier 2-Pole Contactor HN51KC024 for Model CH13NA04800GACAA

This is the factory OEM replacement contactor (part number HN51KC024) for the Carrier CH13NA04800GACAA split-system air conditioner. The contactor is a high-voltage relay controlled by the 24V signal from your thermostat — when the call for cooling comes in, the contactor closes its contacts to send 240V power to the compressor and condenser fan motor. A failed contactor is one of the most common reasons an air conditioner won't turn on, runs continuously without shutting off, or shows signs of pitted or burned terminals that cause voltage drop and compressor damage.

  • Specs: 2-Pole configuration | 24V AC coil voltage | 40-amp contact rating | 240V power circuit | Direct OEM replacement for part number HN51KC024
  • OEM vs Generic: This factory OEM contactor is built to Carrier's exact coil pull-in voltage and contact gap specifications. Generic contactors frequently use lower-grade silver alloy contacts that pit faster under load cycling, leading to premature failure and potential compressor damage from voltage irregularities.
  • Install difficulty: 2/5 — Always shut off power at the disconnect box and verify zero voltage with a multimeter before touching any wiring. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wire positions before removal. Wires transfer one at a time to avoid miswiring.
  • Warranty: 1-year OEM factory warranty against defects. Orders placed before 3PM ship same business day from our climate-controlled warehouse.

Compatibility: Designed and verified for the Carrier CH13NA04800GACAA 4-ton single-stage split-system condenser. Always confirm the coil voltage and pole configuration on your existing contactor's label before ordering. If you have questions about fitment, our HVAC parts specialists verify compatibility before you purchase — no guesswork required. In stock and ready to ship today.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my Carrier CH13NA04800GACAA?
Yes. This is the factory-specified OEM contactor for the Carrier CH13NA04800GACAA. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my Carrier CH13NA04800GACAA?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many Carrier parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my Carrier contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online