{"product_id":"tempstar-transformer-for-t9mpv050f12d1-40va-115v-to-24v-ships-today","title":"Tempstar Transformer for T9MPV050F12D1 — 40VA 115V to 24V | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 40VA control transformer (part #1172810) powers the low-voltage control circuit of your Tempstar T9MPV050F12D1 gas furnace, stepping 115V line voltage down to the 24V used by the control board, gas valve, igniter circuit, and thermostat. A failed transformer cuts power to the entire control system: the thermostat goes dark, the furnace ignores heat calls, and the ignition sequence never starts. Telltale signs include a blown low-voltage control fuse, a humming transformer, or no voltage across the 24V secondary terminals. At 40VA it carries the full control load of this variable-speed furnace with margin to spare.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eControl Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e40VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e115V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the Tempstar T9MPV050F12D1 variable-speed gas furnace. The same 115V-to-24V 40VA transformer is used across many ICP-family furnaces (Tempstar, Heil, Comfortmaker). Verify the part number against your existing unit before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter at the transformer terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the furnace control-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all primary and secondary wire connections before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect the line and 24V leads, then unbolt the failed transformer from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new transformer and reconnect leads exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, confirm 24V across the secondary, and run a complete heat cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlank thermostat and no furnace response to a heat call\u003c\/li\u003e\n\u003cli\u003eRepeatedly blown control-board fuse\u003c\/li\u003e\n\u003cli\u003eAudible buzzing or humming from the transformer\u003c\/li\u003e\n\u003cli\u003eNo 24V reading at the secondary terminals\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021679772019,"sku":"1172810-GEN","price":32.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048490615155,"sku":"1172810","price":41.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-transformer-control-1172810_0166e3e4-dfef-4668-9a86-543813b05a11.jpg?v=1782961443","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-transformer-for-t9mpv050f12d1-40va-115v-to-24v-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}