{"product_id":"tempstar-ptac-thermostat-for-teb07r25dca-low-temp-control-with-knob-ships-today","title":"Tempstar PTAC Thermostat for TEB07R25DCA — Low-Temp Control with Knob | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the OEM thermostat control assembly for the Tempstar TEB07R25DCA packaged terminal air conditioner (PTAC). The group includes the PTAC thermostat body (P\/N 1058517), the low-temperature thermostat (P\/N 1059022), and the replacement control knob (P\/N 1058437). Together these manage the unit's 24V control circuit — sensing room temperature and switching the compressor and fan to maintain setpoint, with the low-temp stat providing freeze\/low-ambient protection so the coil and compressor are safeguarded in cold conditions. When a PTAC thermostat fails, the unit either won't respond to setpoint changes, short-cycles, runs continuously, or never calls for cooling\/heating at all. A cracked or stripped knob is the most common nuisance failure, leaving the stat physically present but impossible to adjust.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermostat Part Number\u003c\/td\u003e\n\u003ctd\u003e1058517 (TSTAT PTAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow-Temp Part Number\u003c\/td\u003e\n\u003ctd\u003e1059022 (TSTAT LOW TEMP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKnob Part Number\u003c\/td\u003e\n\u003ctd\u003e1058437 (KNOB TSTAT PTAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003ePTAC Mechanical Thermostat with Low-Temp Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eBuilt for the Tempstar TEB07R25DCA and shared across the ICP\/Tempstar\/Heil PTAC family that uses this knob-style mechanical thermostat with low-temperature protection. Verify your existing knob and stat profile match before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power and verify zero voltage with a multimeter on the 24V control terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the front control panel to expose the thermostat assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire on the thermostat terminals before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Pull the knob, release the mounting, and disconnect the thermostat and low-temp stat leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new thermostat and low-temp control, reconnect per your photo, and press on the new knob.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the unit cycles on and off correctly across the knob range.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnit ignores setpoint changes or won't turn on\/off at the knob.\u003c\/li\u003e\n\u003cli\u003eCracked, loose, or stripped control knob that won't adjust the stat.\u003c\/li\u003e\n\u003cli\u003eShort-cycling or continuous running regardless of room temperature.\u003c\/li\u003e\n\u003cli\u003eNo low-temp protection — coil frosting or compressor running in cold ambient.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021645037939,"sku":"1058437-GEN","price":58.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048476098931,"sku":"1058437","price":76.64,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-thermostat-nonprogrammable-1058437_e7bd9a23-04be-4592-998f-b3e39062af88.jpg?v=1782960909","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-ptac-thermostat-for-teb07r25dca-low-temp-control-with-knob-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}