{"product_id":"tempstar-defrost-control-board-for-t4h430gkc200-heat-pump-ships-today","title":"Tempstar Defrost Control Board for T4H430GKC200 — Heat Pump | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM defrost control board (part 1173636) manages the defrost logic for the Tempstar T4H430GKC200 heat pump. During cold-weather operation, frost builds on the outdoor coil and chokes heat transfer; the defrost board monitors coil temperature and run time, then initiates a defrost cycle — energizing the reversing valve, stopping the outdoor fan, and timing the cycle so the coil clears without wasting energy. A failed board leaves the outdoor coil iced over, kills heating capacity, or traps the unit in a continuous or never-triggering defrost state. Symptoms include a frozen outdoor unit, no heat, the unit stuck in defrost, or erratic fan and reversing-valve behavior.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1173636\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefrost Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eHeat Pump Defrost Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFits the Tempstar T4H430GKC200 and matching ICP\/Heil\/Comfortmaker heat-pump chassis that use this defrost board. Match the board's part number and connector layout to your existing board before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and disconnect; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control-box access panel on the outdoor unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every plug and terminal on the board, and note the defrost-timing jumper\/pin setting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug the harnesses, release the standoffs or screws, and lift out the old board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new board, transfer all connectors per your photo, and set the defrost-timing pins to match the original.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, initiate heating, and confirm normal operation and a proper forced\/timed defrost cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor coil frozen over with no defrost\u003c\/li\u003e\n\u003cli\u003eUnit stuck running defrost continuously\u003c\/li\u003e\n\u003cli\u003eNo heat output in heat-pump mode\u003c\/li\u003e\n\u003cli\u003eOutdoor fan or reversing valve cycling erratically\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021787152755,"sku":"1173636-GEN","price":149.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048443855219,"sku":"1173636","price":193.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-defrost-1173636_4bc145be-1023-4f57-bda5-d5094b071cd1.jpg?v=1782959818","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-defrost-control-board-for-t4h430gkc200-heat-pump-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}