{"product_id":"tempstar-defrost-control-board-for-t2h360gkd100-heat-pump-ships-today","title":"Tempstar Defrost Control Board for T2H360GKD100 — Heat Pump | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM defrost control board (part number 1173636) is the logic center of the Tempstar T2H360GKD100 heat pump's outdoor section. In heating mode it monitors coil temperature and run time, then commands a defrost cycle — reversing the system and shutting off the outdoor fan to melt frost off the outdoor coil — before returning to normal heating. It also coordinates the reversing valve, condenser fan, and compressor timing. When this board fails, the outdoor coil ices over solid, heating capacity drops, the unit may run constantly, or it may never enter defrost at all. Other symptoms include the outdoor fan behaving erratically, no compressor operation, or the reversing valve failing to shift. A failed defrost board is a frequent cause of winter no-heat and frozen-coil complaints.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1173636\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefrost Control Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDefrost timing, fan \u0026amp; reversing-valve control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered as a direct-fit replacement for the Tempstar T2H360GKD100 heat pump and equivalent ICP, Heil, and Comfortmaker units sharing the same outdoor control platform. Match the board's part number and connector layout to your original before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect outdoor power and verify zero voltage with a multimeter before touching the board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical-compartment service panel to expose the control board.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire harness, sensor lead, and the defrost timing-pin setting before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unplug each connector, release the board's standoffs or screws, and lift the old board out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Seat the new board, set the defrost interval pins to match the original, and reconnect every harness per your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, confirm normal heating operation, and verify a forced\/initiated defrost cycle runs and terminates correctly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor coil ices over and never defrosts.\u003c\/li\u003e\n\u003cli\u003eHeat pump runs constantly or won't produce heat.\u003c\/li\u003e\n\u003cli\u003eOutdoor fan or reversing valve behaves erratically.\u003c\/li\u003e\n\u003cli\u003eNo compressor operation despite a heating call.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021819167091,"sku":"1173636-GEN","price":159.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048439988595,"sku":"1173636","price":207.94,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-control-board-defrost-1173636_39949dc6-ca0e-4ad2-bb16-24865f2b8b1d.jpg?v=1782959674","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-defrost-control-board-for-t2h360gkd100-heat-pump-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}