{"product_id":"tempstar-contactor-for-t4h442gkb200-1-pole-30a-24v-coil-ships-today","title":"Tempstar Contactor for T4H442GKB200 — 1-Pole 30A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM single-pole definite purpose contactor (Tempstar part number 1172472) is the electrically-controlled switch that energizes the compressor and condenser fan in your Tempstar T4H442GKB200 heat pump. Rated for 30 amps with a 24-volt control coil and an integrated shunt, it closes whenever the thermostat calls for cooling or heating and opens to de-energize the outdoor unit. A failed contactor is one of the most common no-cooling and no-heat causes: pitted or welded contacts keep the compressor running, while a burned-out coil prevents the unit from starting at all. Replacing it restores reliable, safe switching of the high-voltage line to your compressor.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor, Single-Pole (1P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eIntegrated Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the Tempstar T4H442GKB200 heat pump condensing unit. Because this is the genuine 1172472 contactor, it is also shared across many ICP-family outdoor units (Tempstar, Heil, Comfortmaker, Arcoaire). Always confirm your existing contactor is a 1-pole 30A unit with a 24V coil before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage at the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wiring before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the wires, then unscrew the old contactor from its mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1172472 contactor and reconnect each wire exactly per your photo, confirming the 24V coil leads land on the coil terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contactor pulls in on a call and drops out cleanly when satisfied.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompressor and fan won't start even though the thermostat is calling.\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit.\u003c\/li\u003e\n\u003cli\u003ePitted, blackened, or welded contacts visible on the old part.\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs continuously and won't shut off (stuck closed).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021785579891,"sku":"1172472-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048425996659,"sku":"1172472","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_aac3fefe-cc9a-4e80-94a2-fb9d5eebb1a8.jpg?v=1782959157","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-contactor-for-t4h442gkb200-1-pole-30a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}