{"product_id":"tempstar-contactor-for-t4h430gkd200-1-pole-30a-24v-coil-w-shunt-ships-today","title":"Tempstar Contactor for T4H430GKD200 - 1-Pole 30A 24V Coil w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 1-pole definite-purpose contactor (OEM part #1172472) is the main switching relay for the Tempstar T4H430GKD200 heat pump. Rated at 30 amps with a 24-volt control coil and an integrated shunt, it passes line voltage to the compressor and condenser fan motor every time the thermostat calls. When the coil energizes, the silver-alloy contacts close and start the outdoor unit. Repeated cycling pits and burns those contacts and weakens the coil, so the contactor is a routine wear item and a leading cause of an outdoor unit that hums but will not start.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-purpose contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1-pole, single-pole with shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eT4H430GKD200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered for the Tempstar T4H430GKD200 condensing unit and shared across many ICP-family heat pumps and air conditioners (Heil, Comfortmaker, Arcoaire) that use the 1172472 contactor. Verify the existing part number and coil voltage before installing.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e - Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e - Remove the condenser service panel to expose the control area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e - Photograph all line, load, and 24V coil wires before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e - Note wire positions, disconnect the line, load, and coil leads, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e - Mount the new contactor and reconnect every wire exactly as photographed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e - Restore power and confirm the contactor pulls in and the compressor and fan start on a call.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor and fan will not start\u003c\/li\u003e\n\u003cli\u003eVisibly burned, pitted, or welded contacts\u003c\/li\u003e\n\u003cli\u003eContactor chatters or fails to pull in when the thermostat calls\u003c\/li\u003e\n\u003cli\u003eDebris or insects holding the contacts open\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021786825075,"sku":"1172472-GEN","price":32.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048425898355,"sku":"1172472","price":41.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_289a1d2f-ae76-4840-a43e-4fe6794ba8b6.jpg?v=1782959150","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-contactor-for-t4h430gkd200-1-pole-30a-24v-coil-w-shunt-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}