{"product_id":"tempstar-contactor-for-t4h424gkd100-1-pole-30a-24v-coil-w-shunt-ships-today","title":"Tempstar Contactor for T4H424GKD100 — 1-Pole 30A 24V Coil w\/Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM single-pole definite-purpose contactor (part number 1172472) is the high-voltage switch that energizes the compressor and condenser fan in your Tempstar T4H424GKD100 heat pump. When the thermostat calls for cooling or heating, the low-voltage 24V control circuit energizes the contactor coil, pulling the contacts closed and sending line voltage to the outdoor unit. The integrated shunt provides a controlled path that keeps power flowing to the run circuit even when the contacts open. Rated for 30 amps with a 24-volt coil, this 1-pole contactor is a common wear item — the contacts arc and pit every time they open and close, and the coil can burn out over thousands of cycles. A failing contactor is one of the most frequent causes of an outdoor unit that hums but won't start, or that won't shut off when the thermostat is satisfied.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eWith Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThis contactor is the factory-specified part for the Tempstar T4H424GKD100 heat pump. Because it is shared across the ICP family (Tempstar, Heil, Comfortmaker, Arcoaire), it also services many comparable single-stage condensing and heat-pump units of the same era. Always confirm the existing contactor's pole count, amp rating, and 24V coil before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and the breaker, then verify zero voltage across the line terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel on the side of the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and pull the line, load, and 24V coil leads; unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, transfer the wires to the matching terminals per your photo, confirm the shunt connection is correct.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and call for cooling; verify the contacts pull in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor won't start.\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts visible on the old part.\u003c\/li\u003e\n\u003cli\u003eUnit won't turn off when the thermostat is satisfied (stuck contacts).\u003c\/li\u003e\n\u003cli\u003eChattering or intermittent clicking from the contactor coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021787545971,"sku":"1172472-GEN","price":32.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048425800051,"sku":"1172472","price":42.84,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_251dccd7-16e8-45fe-8793-ecbc781ef31d.jpg?v=1782959143","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-contactor-for-t4h424gkd100-1-pole-30a-24v-coil-w-shunt-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}