{"product_id":"tempstar-contactor-for-t4h418gkb100-1-pole-30a-24v-coil-ships-today","title":"Tempstar Contactor for T4H418GKB100 — 1-Pole 30A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM single-pole contactor (part #1172472) is the primary switching relay for the Tempstar T4H418GKB100 heat pump. Rated at 30 amps with a 24-volt coil and an integrated shunt, it energizes the compressor and condenser fan motor whenever the thermostat calls for cooling or heating. When the 24V coil is energized, the electromagnet pulls the contacts closed to deliver line voltage to the compressor. A failed contactor is one of the most common causes of a no-cool \/ no-heat condition: pitted or welded contacts, a chattering hum, or a burned-out coil will stop the outdoor unit from starting even though the thermostat is calling.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-Pole (1P) Definite Purpose Contactor with Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the Tempstar T4H418GKB100 condensing unit and shared across many ICP \/ Heil \/ Comfortmaker \/ Tempstar single-stage heat pump and AC platforms using a 30A 1-pole control. Always confirm amperage, pole count, and coil voltage against the contactor currently installed in your unit.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control-panel service cover on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the wires, then unscrew the old contactor from the mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect line, load, and the two 24V coil leads exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contacts pull in and the compressor\/fan energize on a call.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit won't start but the thermostat is calling for cooling\/heating\u003c\/li\u003e\n\u003cli\u003eLoud buzzing or chattering from the contactor\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eCoil reads open on a continuity test\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021788496243,"sku":"1172472-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048425537907,"sku":"1172472","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_74fce4e8-d6fe-49a6-ad74-cc7a9b31cd69.jpg?v=1782959125","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-contactor-for-t4h418gkb100-1-pole-30a-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}