{"product_id":"tempstar-contactor-for-t4a336gkn200-1-pole-30a-24v-coil-w-shunt-ships-today","title":"Tempstar Contactor for T4A336GKN200 — 1-Pole 30A 24V Coil w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM single-pole contactor (part number 1172472) is the cooling-cycle switch for the Tempstar T4A336GKN200 air conditioner. Rated 30 amps with a 24-volt coil and integrated shunt, it closes its contacts whenever the thermostat calls for cooling, sending line voltage to the compressor and condenser fan motor. Each cooling cycle arcs the contacts, and over time they pit, burn, and weld, while the coil can fail open. Typical failure symptoms are a humming or chattering condenser that won't start, an AC unit that runs nonstop because the contacts welded closed, or scorched and corroded terminals.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e1-Pole Definite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirectly fits the Tempstar T4A336GKN200 condensing unit. The same 30A 24V single-pole contactor (PN 1172472) is shared across many ICP-family Tempstar, Heil, and Comfortmaker outdoor units. Verify amp rating, pole count, and coil voltage against your existing contactor before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage at the contactor with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit service panel to reach the electrical compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect each wire, then unbolt the failed contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect every wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud hum or buzz from the outdoor unit with no startup.\u003c\/li\u003e\n\u003cli\u003eBurnt, pitted, or welded contacts causing the AC to run continuously.\u003c\/li\u003e\n\u003cli\u003eRapid clicking or chattering on a cooling call.\u003c\/li\u003e\n\u003cli\u003eCoil fails to pull the contacts in when energized.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021811859827,"sku":"1172472-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048423145843,"sku":"1172472","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_93f615da-9e25-41e5-bd14-013b760c1a0c.jpg?v=1782959025","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-contactor-for-t4a336gkn200-1-pole-30a-24v-coil-w-shunt-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}