{"product_id":"tempstar-contactor-for-t2h348gka100-1-pole-30a-24v-w-shunt-ships-today","title":"Tempstar Contactor for T2H348GKA100 — 1-Pole 30A 24V w\/Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM definite-purpose contactor (part number 1172472) is the main switching relay for the Tempstar T2H348GKA100 heat pump. It is a single-pole, 30-amp device driven by a 24-volt control coil and includes an integrated shunt for dependable operation. On a thermostat call, the 24V coil closes the contactor and delivers line voltage to the compressor and condenser fan. Contactors wear out from arcing every time they cycle, making them one of the most common no-cool\/no-heat failures. Typical symptoms include a humming outdoor unit that won't start, pitted or welded contacts, a buzzing chatter, or a condenser that runs continuously because the contacts have welded shut.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor, 1-Pole w\/Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp Rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eT2H348GKA100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the Tempstar T2H348GKA100 condensing unit. This single-pole 30A contactor also serves many ICP-family heat pumps and air conditioners (Heil, Comfortmaker, Arcoaire) sharing the same 24V control platform. Confirm part number 1172472 before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service\/control panel cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wiring before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unscrew the contactor mounting bracket and transfer the line, load, and 24V coil leads one at a time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly per your photo, confirming the 24V coil terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contactor pulls in and the compressor and fan start on a call.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums but the compressor and fan won't start.\u003c\/li\u003e\n\u003cli\u003eBurnt, pitted, or welded contacts visible on the old part.\u003c\/li\u003e\n\u003cli\u003eLoud buzzing or chattering from the contactor when energized.\u003c\/li\u003e\n\u003cli\u003eCondenser runs nonstop because contacts are stuck closed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021819625843,"sku":"1172472-GEN","price":34.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048422818163,"sku":"1172472","price":45.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_cc65a83d-1156-4fc9-9f93-09e938e37777.jpg?v=1782959002","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-contactor-for-t2h348gka100-1-pole-30a-24v-w-shunt-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}