{"product_id":"tempstar-contactor-for-t2h330gkd100-1-pole-30a-24v-coil-w-shunt-ships-today","title":"Tempstar Contactor for T2H330GKD100 — 1-Pole 30A 24V Coil w\/Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine OEM 1-pole definite purpose contactor (Part No. 1172472) for the Tempstar T2H330GKD100 heat pump condensing unit. Rated for 30 amps with a 24-volt control coil and a built-in shunt, the contactor is the high-voltage switch that energizes the compressor and outdoor fan motor whenever the thermostat calls for cooling or heating. When the low-voltage coil receives 24V from the control board, the electromagnet pulls the contacts closed and passes line voltage to the compressor. A failed contactor is one of the most common no-cool\/no-heat service calls — symptoms include a humming outdoor unit that will not start, pitted or welded contacts that keep the compressor running, chattering, or burnt terminals.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eContactor 1-Pole w\/Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose, Single Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Load Amps\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the factory-correct replacement for the Tempstar T2H330GKD100 heat pump. The same 30A 24V single-pole platform is used across many ICP-family condensers and heat pumps sold under Heil, Comfortmaker, Arcoaire and Keeprite brands. Always confirm your existing contactor's amp rating, pole count and coil voltage before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker. Verify zero voltage at the line terminals with a multimeter before touching any wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal position before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load and 24V coil wires, then unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect each wire to the matching terminal per your photo, and confirm the coil leads land on the 24V terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and verify the contacts pull in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums but the compressor will not start\u003c\/li\u003e\n\u003cli\u003ePitted, burnt or welded contacts (unit keeps running with no call)\u003c\/li\u003e\n\u003cli\u003eAudible chattering or buzzing from the contactor\u003c\/li\u003e\n\u003cli\u003eCoil does not pull the contacts in when 24V is applied\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021821526387,"sku":"1172472-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048422687091,"sku":"1172472","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_0f59b6f6-ae4d-41cf-9257-71e8524667e4.jpg?v=1782959000","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-contactor-for-t2h330gkd100-1-pole-30a-24v-coil-w-shunt-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}