{"product_id":"tempstar-contactor-for-t2a324gkd100-1-pole-30a-24v-coil-with-shunt-ships-today","title":"Tempstar Contactor for T2A324GKD100 — 1-Pole 30A 24V Coil with Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM single-pole contactor (part #1172472) is the factory-specified power switch for the Tempstar T2A324GKD100 condensing unit. The contactor uses a 24V control coil to close a 30-amp line-voltage contact set, energizing the compressor and condenser fan motor on every call for cooling. The integrated shunt provides the auxiliary connection point used on this ICP platform. Contactors are wear items — their contacts arc each time they open and close — so pitting, welding, and a weakening coil are among the most common causes of no-cooling and won't-shut-off service calls.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-Pole (1P) Definite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eIncludes shunt connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirectly fits the Tempstar T2A324GKD100 air conditioner. The same 1172472 contactor is shared across many related ICP-built single-stage condensers under the Tempstar, Heil, and Comfortmaker brands. Verify the amp rating, pole count, and 24V coil voltage of your existing contactor before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker. Verify zero voltage at the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical access panel on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire connections, including line, load, coil, and shunt terminals, before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect each lead, unfasten the contactor from its bracket, and lift it out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor in the same orientation and reconnect every wire per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the unit starts without chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit hums but the compressor and fan will not start.\u003c\/li\u003e\n\u003cli\u003eContacts are pitted, burned, or welded shut.\u003c\/li\u003e\n\u003cli\u003eCompressor keeps running after the thermostat is satisfied.\u003c\/li\u003e\n\u003cli\u003eChattering or buzzing from a weak control coil.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021831127411,"sku":"1172472-GEN","price":29.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048421998963,"sku":"1172472","price":38.94,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_addba629-5987-48c0-8c6c-ab6bdec3fb69.jpg?v=1782958953","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-contactor-for-t2a324gkd100-1-pole-30a-24v-coil-with-shunt-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}