{"product_id":"tempstar-40va-transformer-for-tch636gka100-208-230v-to-24v-ships-today","title":"Tempstar 40VA Transformer for TCH636GKA100 — 208\/230V to 24V | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 40VA control transformer (part number 1170676) supplies the low-voltage power your Tempstar TCH636GKA100 system needs to run its thermostat, contactor coil, control board, and safety circuits. It steps the incoming 208\/230V line voltage down to the 24V secondary that nearly every HVAC control component depends on. When a transformer fails, the entire control side of the unit goes dead — the system simply will not respond. A buzzing transformer, a blown low-voltage fuse, or a unit that has power at the disconnect but no thermostat response are classic signs this part has failed and needs replacement.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1170676\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eControl \/ Step-Down Transformer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e40 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Voltage\u003c\/td\u003e\n\u003ctd\u003e208\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as a direct OEM replacement for the Tempstar TCH636GKA100. Because it is a genuine ICP\/Heil-family component, it also fits a wide range of Tempstar, Heil, Comfortmaker, and ICP heat pump and air handler systems that use the 1170676 transformer. Always confirm the part number on your existing transformer before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and service disconnect, then verify zero voltage with a multimeter on both line and load sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the unit's electrical service panel to expose the control box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every primary and secondary wire connection before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line-voltage primary leads and the 24V secondary leads, then unbolt the old transformer from its mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1170676 transformer, then reconnect the primary and secondary wiring exactly as photographed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm 24V across the secondary terminals and proper thermostat\/contactor response.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo 24V at the thermostat or control board despite line voltage being present\u003c\/li\u003e\n\u003cli\u003eRepeatedly blown low-voltage fuses on the control board\u003c\/li\u003e\n\u003cli\u003eAudible buzzing or burning smell from the transformer\u003c\/li\u003e\n\u003cli\u003eSystem completely unresponsive to thermostat calls\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021652279667,"sku":"1170676-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048409612659,"sku":"1170676","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-transformer-control-1170676_7901ba05-cf6b-4ea4-a6c8-9c59d6f69ca1.jpg?v=1782958494","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-40va-transformer-for-tch636gka100-208-230v-to-24v-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}