{"product_id":"tempstar-40a-definite-purpose-contactor-for-tca760gka200-ships-today","title":"Tempstar 40A Definite Purpose Contactor for TCA760GKA200 — Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM 40-amp contactor (part #1176763) is the primary switching relay for the Tempstar TCA760GKA200 condensing unit. When the thermostat calls for cooling, the 24V control circuit energizes the contactor coil, pulling the contacts closed to send line voltage to the compressor and condenser fan motor. Rated for 40 amps, it handles the high inrush current of the compressor on every cycle. Contacts pit, burn, and weld over thousands of cycles. Failure symptoms include a unit that won't start, chattering or buzzing at the contactor, a condenser that runs continuously even after the call for cooling ends, and visible arcing or burnt\/pitted contacts.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1176763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e40 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eTCA760GKA200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eBuilt for the Tempstar TCA760GKA200 and compatible across ICP \/ Tempstar \/ Heil \/ Comfortmaker condensing units that call for a 40A 24V-coil contactor. Verify amp rating, pole count, and coil voltage against your existing contactor before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in and the unit starts cleanly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnit won't start or starts intermittently\u003c\/li\u003e\n\u003cli\u003eLoud buzzing or chattering at the contactor\u003c\/li\u003e\n\u003cli\u003eBurnt, pitted, or welded contacts\u003c\/li\u003e\n\u003cli\u003eCompressor keeps running after the thermostat is satisfied\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63027259572595,"sku":"1176763-GEN","price":32.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048400798067,"sku":"1176763","price":42.84,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1176763_d353de54-6c8d-46e1-9ad6-d882fbd4a7ec.jpg?v=1782958173","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-40a-definite-purpose-contactor-for-tca760gka200-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}