{"product_id":"tempstar-40a-contactor-for-t2a360gkd300-24v-coil-oem-1176763-ships-today","title":"Tempstar 40A Contactor for T2A360GKD300 — 24V Coil OEM 1176763 | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine OEM Tempstar 40-amp definite-purpose contactor (part number 1176763) for the T2A360GKD300 air conditioner. The contactor is the high-current switch that connects line voltage to the compressor and condenser fan motor whenever the thermostat calls for cooling. Its 24-volt control coil is energized by the low-voltage circuit, pulling the contacts closed to start the system. Because the contacts arc and carry heavy load every cycle, they are one of the most common wear items in an outdoor unit. Failure symptoms include pitted or welded contacts that keep the compressor running continuously, a buzzing or humming coil that won't pull in, and an outdoor unit that simply won't start even though the thermostat is calling.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1176763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e40 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eT2A360GKD300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the Tempstar T2A360GKD300 condensing unit and the shared ICP \/ Heil \/ Comfortmaker platforms that specify part 1176763. Verify the amp rating (40A) and coil voltage (24V) against your existing contactor before installing, as definite-purpose contactors are interchangeable only when those ratings and the pole count match.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical-compartment service panel on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time, or label them, then unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit won't start on a cooling call\u003c\/li\u003e\n\u003cli\u003eCompressor runs continuously and won't shut off (welded contacts)\u003c\/li\u003e\n\u003cli\u003eLoud buzzing or humming from the contactor coil\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or corroded contact points\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63027260391795,"sku":"1176763-GEN","price":32.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048398897523,"sku":"1176763","price":42.84,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1176763_0653c987-c503-4f11-b794-cfe5464486b5.jpg?v=1782958125","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-40a-contactor-for-t2a360gkd300-24v-coil-oem-1176763-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}