{"product_id":"tempstar-2-pole-40a-contactor-for-t4h360gka100-24v-coil-ships-today","title":"Tempstar 2-Pole 40A Contactor for T4H360GKA100 — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the OEM 2-pole, 40-amp contactor (Part #1172786) with a 24V coil for the Tempstar T4H360GKA100 heat pump. The contactor is the heavy-duty relay that the thermostat (via the 24V control circuit) uses to switch high-voltage line power to the compressor and condenser fan motor. Contactors wear out: the silver contacts pit and burn, the coil weakens, and the points can stick closed or chatter. A failed contactor is one of the most common reasons a condensing unit won't start, hums, or runs when it shouldn't.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172786\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e2-Pole Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCompressor \u0026amp; Condenser Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eT4H360GKA100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the Tempstar\/Heil\/ICP T4H360GKA100. This 2-pole 40A\/24V contactor is interchangeable across many ICP-family condensing units of the same rating — confirm pole count, amp rating, and 24V coil voltage match before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and disconnect, and verify zero voltage with a multimeter on the line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the outdoor unit's electrical service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Move wires one at a time from the old contactor to the new one (transfer in place to avoid mistakes), then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1172786 contactor and verify every terminal matches your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in and the compressor\/fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnit hums but compressor and fan won't start.\u003c\/li\u003e\n\u003cli\u003eBurnt, pitted, or welded contacts.\u003c\/li\u003e\n\u003cli\u003eChattering or buzzing contactor on a cooling call.\u003c\/li\u003e\n\u003cli\u003eCondenser keeps running after the thermostat is satisfied (stuck contacts).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021791117683,"sku":"1172786-GEN","price":36.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048394539379,"sku":"1172786","price":46.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1172786_ca7e12b2-e3a6-43aa-904b-98b671338d98.jpg?v=1782437342","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-2-pole-40a-contactor-for-t4h360gka100-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}