{"product_id":"tempstar-2-pole-40a-contactor-for-t2a360gkd200-24v-coil-oem-1172786-ships-today","title":"Tempstar 2-Pole 40A Contactor for T2A360GKD200 — 24V Coil OEM 1172786 | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine OEM Tempstar 2-pole, 40-amp definite-purpose contactor (part number 1172786) for the T2A360GKD200 air conditioner. The contactor is the heavy-duty switch that connects line voltage to the compressor and condenser fan on a call for cooling. Its 24-volt control coil is energized by the thermostat circuit, which magnetically pulls both poles of contacts closed. Switching high current on every cycle, the contacts gradually pit, burn, and can eventually weld shut or fail to close. Typical symptoms are an outdoor unit that won't start, a compressor that runs nonstop because the contacts are welded, or a loud humming coil that can't pull the contacts in.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172786\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e40 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eT2A360GKD200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eBuilt for the Tempstar T2A360GKD200 condensing unit and the shared ICP \/ Heil \/ Comfortmaker platforms that specify part 1172786. Match the pole count (2), amp rating (40A), and coil voltage (24V) to your existing contactor before installing — these are the three ratings that determine interchangeability.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Shut off power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical-compartment service panel on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer or label the wires one at a time, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 2-pole contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit won't start on a cooling call\u003c\/li\u003e\n\u003cli\u003eCompressor runs continuously and won't shut off (welded contacts)\u003c\/li\u003e\n\u003cli\u003eLoud buzzing or humming from the contactor coil\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or corroded contact points\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021822706035,"sku":"1172786-GEN","price":31.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048393654643,"sku":"1172786","price":41.54,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1172786_5c5a327e-b504-40e7-83c2-fb8b714ac30d.jpg?v=1782957733","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-2-pole-40a-contactor-for-t2a360gkd200-24v-coil-oem-1172786-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}