{"product_id":"tempstar-1-pole-40a-contactor-for-tsh560gka100-24v-coil-ships-today","title":"Tempstar 1-Pole 40A Contactor for TSH560GKA100 — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 40-amp contactor (part #1176763) is the high-voltage switch that powers the compressor and outdoor fan on the Tempstar TSH560GKA100 heat pump. Its 24V coil is energized by the thermostat through the control circuit; when energized, the contacts close and send line voltage to the compressor and condenser fan. Over time the silver contacts pit, burn, and weld from the constant arcing of high inrush current. A failing contactor causes a unit that won't start, a humming or chattering coil, or — when contacts weld shut — a compressor that runs continuously and won't shut off even when the thermostat is satisfied.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1176763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCondenser \/ Compressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the Tempstar TSH560GKA100 series and equivalent Heil, Comfortmaker, and ICP-built units using 40A contactor 1176763. Confirm amperage, pole count, and 24V coil rating against your existing contactor before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the outdoor service panel to expose the contactor and wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every line, load, and 24V coil connection before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unbolt the failed contactor and transfer wires one at a time to avoid mix-ups.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect line, load, and coil leads per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in cleanly without chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit is silent and won't start on a cooling call\u003c\/li\u003e\n\u003cli\u003eContactor hums, buzzes, or chatters instead of pulling in\u003c\/li\u003e\n\u003cli\u003eBurned, pitted, or welded contacts visible on inspection\u003c\/li\u003e\n\u003cli\u003eCompressor runs nonstop and won't shut off\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021630390643,"sku":"1176763-GEN","price":29.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048389689715,"sku":"1176763","price":37.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1176763_b90f56ce-e1ec-46d1-9573-ffd885874b7c.jpg?v=1782957518","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-1-pole-40a-contactor-for-tsh560gka100-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}