{"product_id":"tempstar-1-pole-30a-contactor-for-tsh430gka101-24v-coil-w-shunt-ships-today","title":"Tempstar 1-Pole 30A Contactor for TSH430GKA101 — 24V Coil w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the OEM single-pole definite purpose contactor (Part No. 1172472) for the Tempstar TSH430GKA101 heat pump\/condensing unit. Rated for 30 amps with a 24-volt coil and an integrated shunt, the contactor is the electrically operated switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling or heat-pump operation. When the 24V coil is energized, the contacts pull in and pass line voltage to the outdoor unit; when the call ends, the contacts open and the unit shuts down. A worn or pitted contactor is one of the most common causes of an outdoor unit that hums, chatters, fails to start, or runs continuously.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor, 1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmp Rating\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eIntegrated shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the factory replacement for the Tempstar TSH430GKA101 outdoor unit. The same 30A 1-pole 24V definite purpose contactor is used across many ICP-family condensers and heat pumps sold under the Tempstar, Heil, Comfortmaker, and Arcoaire brands. Always confirm your existing contactor's amp rating, pole count, and coil voltage before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and the breaker, then verify zero voltage at the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal position before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect each wire to the matching terminal per your photo, and confirm the shunt orientation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and call for cooling; verify the contacts pull in cleanly and the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor will not start.\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded contacts.\u003c\/li\u003e\n\u003cli\u003eChattering or rapid clicking at the contactor when cooling is called.\u003c\/li\u003e\n\u003cli\u003eUnit runs continuously and will not shut off (welded contacts).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021632618867,"sku":"1172472-GEN","price":24.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048387428723,"sku":"1172472","price":31.2,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_bb99532a-0f55-4d03-8aa2-6c346c2516e6.jpg?v=1782957342","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-1-pole-30a-contactor-for-tsh430gka101-24v-coil-w-shunt-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}