{"product_id":"tempstar-1-pole-30a-contactor-for-t4h348gke100-24v-coil-w-shunt-ships-today","title":"Tempstar 1-Pole 30A Contactor for T4H348GKE100 — 24V Coil w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM single-pole definite purpose contactor (part #1172472) is the electromechanical switch that energizes the compressor and condenser fan in your Tempstar T4H348GKE100 heat pump. When the 24-volt control circuit calls for cooling or heating, the low-voltage coil pulls the contacts closed and sends line voltage to the compressor. The integrated shunt provides a parallel current path that reduces arcing and extends switching life. A failed contactor is among the most common causes of an outdoor unit that won't start — you may hear a faint hum, find pitted or welded contacts, or see the compressor and fan stay off despite a thermostat call. Rated at 30 amps with a 24V coil, this is the exact replacement specified for this model.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-Pole (1P) Definite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTempstar (ICP \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eIntegrated shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirectly fits the Tempstar T4H348GKE100 heat pump and shares the same platform as comparable ICP, Heil, Comfortmaker, and Carrier-family condensing units using a 30A 1-pole 24V contactor. Confirm the part number on your existing contactor before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical access panel on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wiring before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to match your photo, confirming the 24V coil leads land on the coil terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and verify the contacts pull in and the compressor and fan start on a cooling call.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuzzing or chattering from the outdoor unit with no compressor start\u003c\/li\u003e\n\u003cli\u003ePitted, blackened, or welded (stuck-closed) contacts\u003c\/li\u003e\n\u003cli\u003eUnit runs continuously even after the thermostat is satisfied\u003c\/li\u003e\n\u003cli\u003eCoil reads open or out-of-spec on a multimeter\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"Tempstar","offers":[{"title":"Direct Replacement","offer_id":63021791248755,"sku":"1172472-GEN","price":26.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63048386052467,"sku":"1172472","price":35.04,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_5e736ed5-b84d-4823-84e0-6dcf4809a5f9.jpg?v=1782957233","url":"https:\/\/nationalhvacparts.com\/products\/tempstar-1-pole-30a-contactor-for-t4h348gke100-24v-coil-w-shunt-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}